Refill, Flow & Time
Tank Refill Time Calculator
Refill time is a simple division — volume divided by flow — but only if both numbers describe the same thing. The volume must be the amount you actually need to add, and the flow must be the rate that genuinely reaches the tank. A pump nameplate rating is often far higher than its delivery at the working head, and water is usually being drawn at the same time.
This calculator converts a wide range of volume and flow units into litres and litres per minute, subtracts any concurrent use, and returns the fill time in the most readable unit from seconds to days. If consumption equals or exceeds the incoming flow, it tells you plainly that the tank will never fill.
Calculator
How to use this calculator
- Enter the tank volume, or the volume you actually need to add if it is partly full. Use a volume calculator first if you only know the dimensions.
- Enter the delivery rate in any supported unit. A timed bucket test at the tank inlet is more reliable than a pump nameplate, because head and pipe friction reduce real flow.
- Set the fill percentage. For a tank that is already 40% full, enter 60 to calculate the top-up only.
- If water is being drawn during the fill, enter that rate with the same unit as the inflow. Read the result in seconds, minutes, hours or days.
The formula
fillVolume = tankVolume × fill% ÷ 100netRate = flowIn − waterUsedWhileFillingtime = fillVolume ÷ netRatehours = minutes ÷ 60 · days = minutes ÷ 1440If netRate ≤ 0, the tank will never fill.
Variables
| Symbol | Meaning | Unit | Note |
|---|---|---|---|
V | Tank volume | L (after conversion) | Total capacity before applying the fill percentage. |
Qin | Incoming flow | L/min | Actual delivery at the tank inlet. |
Quse | Concurrent use | L/min | Water drawn while the tank is filling. |
netRate | Net fill rate | L/min | Must be positive for the tank to fill. |
fill% | Portion to fill | % | 100% for a full tank from empty. |
Flow unit conversion reference
| Unit | Equivalent in L/min |
|---|---|
| L/hour | 0.01667 |
| m³/hour | 16.667 |
| US gal/min | 3.7854 |
| US gal/hour | 0.0631 |
| Imperial gal/min | 4.5461 |
Conversions use exact definitions: 1 US gallon = 3.785411784 L and 1 Imperial gallon = 4.54609 L.
Typical pump flows versus refill time
For a 1,000 L tank filled from empty: 10 L/min takes about 100 minutes, 20 L/min about 50 minutes, 40 L/min about 25 minutes and 100 L/min about 10 minutes. A 5 US gpm pump delivers roughly 19 L/min and takes about 53 minutes; a 1 m³/h supply takes about an hour.
A household pump commonly delivers 10–50 L/min in practice. Always check the pump curve at the actual lift rather than using the maximum free-flow figure.
Estimating the flow you need
Rearrange the formula to size a supply: required flow = volume ÷ longest acceptable fill time. If you need 5,000 L in four hours, you need at least 20.8 L/min reaching the tank. Add allowance for any water used during that window and for a pump that will slow as the tank level rises.
Worked example
A 1,000 L rooftop tank is 40% full. A bucket test shows 18 L/min arriving while the house draws 3 L/min.
- Volume needed = 1,000 × (100 − 40)% = 600 L.
- Net fill rate = 18 − 3 = 15 L/min.
- Top-up time = 600 ÷ 15 = 40 minutes.
- Without household use the same top-up takes 600 ÷ 18 ≈ 33.3 minutes.
- Filling the tank completely from empty would take 1,000 ÷ 15 ≈ 66.7 minutes.
Result: About 40 minutes to top up from 40% to full under simultaneous household use.
Frequently asked questions
How long does it take to fill a 1,000-litre tank?
Divide 1,000 by the net litres per minute. At 20 L/min it takes 50 minutes, at 10 L/min about 100 minutes and at 40 L/min about 25 minutes.
Should I use the pump rated maximum flow?
No. Rated maximum is usually at zero lift. Use the flow at your working head from the pump curve, or measure it with a timed bucket at the tank inlet.
How do I calculate tank refill time manually?
Convert the volume needed and the incoming flow to the same units, subtract any water being used, then divide volume by net flow.
What is a typical household pump flow rate?
Around 10–50 L/min, roughly 2.6–13 US gallons per minute, depending on pump size and the height it must lift.
Does pipe diameter affect refill time?
Yes. At a fixed velocity a pipe with twice the diameter carries four times the flow. Under a fixed pressure drop the gain is larger because flow scales roughly with diameter to the 2.63 power.
How long does a garden hose take to fill a 500-gallon tank?
A typical hose delivers 15–25 L/min. That is about 1,900 L, so 75–125 minutes, before allowing for the house using water at the same time.
My flow is only in m³/hour — what do I enter?
Select the m³/hour unit in the flow selector. Internally it is multiplied by 1,000 and divided by 60 to give litres per minute.
Sources and verification
- NIST Guide to the SI — Exact definitions of litre, gallon and cubic foot.
- US Bureau of Reclamation — Water Measurement Manual — Guidance on measuring discharge in pipes and channels.
- USGS Water Science School — Background on water volume and discharge measurement.
Formula verification uses published references and hand-checked examples. We do not claim a named professional has reviewed this page; the method and sources are published instead.
Results are estimates for general information, based on standard geometry, hydraulics and published reference values. They are not engineering, medical, legal or professional advice. Verify critical calculations with a qualified professional and check local requirements.
Keep calculating
Water Flow Rate Calculator
Convert pipe diameter and velocity — or a timed volume — into flow in nine common units.
Tank Drainage Time Calculator
Estimate how long it takes to empty a tank by steady pumping or by gravity through an outlet.
Pump Horsepower Flow Rate Calculator
Convert pump power, flow and head in either direction, with efficiency and a standard motor size.
How Long Will My Tank Last Calculator
Find out how many days or hours a partly full tank will supply your household, allowing for inflow.