Water Treatment

TDS Water Calculator

A TDS pen gives a fast, approximate picture of how much dissolved material is in water. It does not identify what is there, and it cannot tell you whether the water is safe. This tool places your reading in the WHO palatability bands, compares it with the EPA secondary guideline and converts it to electrical conductivity using your meter factor.

The conversion factor matters because It is set by the mix of salts in the water. If you do not know which scale your meter uses, leave the default at 0.64. Changing the factor alters the EC estimate but does not change the taste band your reading falls into.

Calculator

How to use this calculator

  1. Rinse the probe and measure a clean sample in a glass, stirring gently to remove bubbles. Wait for the reading to settle.
  2. Enter the value in ppm or mg/L. The two are numerically identical for water.
  3. Choose the conversion factor from your meter manual. Leave it at 0.64 if you are unsure.
  4. Read the WHO taste band, the EPA comparison, the EC estimate and the parts-per-thousand value below.
  5. Remember that a low TDS does not indicate safety. Test specifically for microbes, lead, arsenic and nitrate when the source is uncertain.

The formula

TDS (ppm) = EC (µS/cm) × factor
Therefore EC = TDS ÷ factor
ppt = TDS ÷ 1000
Common factors: 0.50 (NaCl), 0.64 (general), 0.70 (442 scale). 1 ppm ≈ 1 mg/L in water.

Variables

SymbolMeaningUnitNote
TDSTotal dissolved solidsppm / mg/LThe meter reading you enter.
ECElectrical conductivity at 25 °CµS/cmEstimated from TDS and the chosen factor.
factorMeter conversion factor—Set by the meter scale and the dissolved salts.
pptParts per thousand—TDS divided by 1,000.

WHO taste bands and the EPA guideline

WHO does not set a health-based limit for TDS; it describes palatability. Below 300 mg/L water is described as excellent, 300–600 good, 600–900 fair, 900–1,200 poor, and above roughly 1,200 unacceptable. EPA has a secondary, non-enforceable guideline of 500 mg/L for taste, colour and scaling, not for health.

BandTDS (mg/L)Typical observation
Excellent0–300Crisp taste, little scaling
Good300–600Some mineral taste
Fair600–900Noticeable taste and scale
Poor900–1,200Salty or bitter
Unacceptableover 1,200Palatability declines sharply

What a TDS meter is useful for

  • Checking whether a reverse-osmosis membrane is working, by comparing feed and product water.
  • Watching for a sudden change in a familiar source.
  • Managing nutrient strength in hydroponics and aquariums, where EC is the primary measure.
  • Estimating scaling tendency in kettles and hot-water systems, alongside a hardness test.

For coffee, the Specialty Coffee Association suggests around 150 mg/L, with roughly 75–250 mg/L generally acceptable.

What TDS cannot tell you

TDS cannot detect bacteria, viruses, lead, arsenic, nitrate or pesticides. Water at 80 ppm can be contaminated and water at 500 ppm can be perfectly safe. A meter also uses a fixed conversion factor, so its EC figure is an estimate: only an evaporation-and-weighing laboratory measurement gives true TDS. Private wells and any source with an unusual taste, odour or colour should be tested in a certified laboratory. Do not treat a good TDS band as a safety certificate.

Worked example

A TDS pen using the 0.64 general scale reads 320 ppm.

  1. EC = TDS ÷ factor = 320 ÷ 0.64 = 500 µS/cm at 25 °C.
  2. ppt = 320 ÷ 1,000 = 0.320 ppt.
  3. 320 mg/L falls in the 300–600 band, described as Good taste.
  4. 320 mg/L is below the EPA 500 mg/L secondary guideline.
  5. No RO is needed for taste at this level, though the result says nothing about microbes or metals.

Result: 320 ppm, about 500 µS/cm, 0.320 ppt — a good-taste band and within the EPA secondary guideline.

Frequently asked questions

What is a good TDS level for drinking water?

WHO calls below 300 mg/L excellent and 300–600 mg/L good. EPA has a non-enforceable secondary guideline of 500 mg/L. These are taste and appearance bands, not safety thresholds.

Can a TDS meter tell me if my water is safe?

No. It only estimates total dissolved ions. Bacteria, lead, arsenic and nitrate can all be present at very low TDS. Test for those specifically.

Is TDS the same as ppm?

In water, ppm and mg/L are numerically the same, so a TDS pen reading 150 ppm corresponds to about 150 mg/L of dissolved solids.

Is TDS the same as water hardness?

No. Hardness counts calcium and magnesium only. TDS counts all dissolved ions, including sodium and chloride, so softened water can still have a high TDS.

What is the difference between TDS and EC?

EC measures how well water conducts electricity; TDS is estimated from EC using a conversion factor. The factor depends on the salts present, which is why meter readings are approximate.

How do I lower TDS in my water?

Reverse osmosis, distillation and deionisation reduce TDS. Blending with lower-TDS water also helps. Choose the method based on which contaminants you actually need to remove.

Is very low TDS water bad for you?

Not inherently. Very low TDS water can taste flat and is more corrosive to some plumbing, but most people get minerals chiefly from food. Remineralisation is usually a taste or corrosion decision.

Sources and verification

Formula verification uses published references and hand-checked examples. We do not claim a named professional has reviewed this page; the method and sources are published instead.

Results are estimates for general information, based on standard geometry, hydraulics and published reference values. They are not engineering, medical, legal or professional advice. Verify critical calculations with a qualified professional and check local requirements.

Keep calculating